SKYLINE : Fire-Proof Test
Standards : BS 8414-1:202 / GB/T 29416:2012
Wind Speed Sensor : 0-10M/S, With An Accuracy Of 0.1M/S
Electrical Requirements : 220V, 50HZ, 5A
Ignited Time : Automatically Determined
The Test Overtemperature : Automatically Distinguished
Fire-Proof Test For Outer Wall External Thermal Insulation Systen
Product introduction
The window fire test model simulates a vertical building surface consisting of a main wall and a vertical auxiliary wall.
The external thermal insulation system is installed on the building surface. The opening of the combustion chamber at the bottom of the test model simulates the windows or openings of the floor in the actual building. The ignited wood or gas flame overflows from the window to simulate the fire after ignition in the room. When a flame overflows from a window or hole, it attacks the external thermal insulation system, checks the damage degree of the external thermal insulation system, and judges its flame propagation. The total heat released in 30 minutes is about 4500 MJ, and the peak heat release rate is about (3 + 0.5) MW.
Standard : BS 8414-1:202 / GB/T 29416:2012
Performance characteristics
1. The test system provides the ignition alarm after 5 minutes. When ignited, the test start time can be automatically determined. At the same time, the test overtemperature can be automatically distinguished. At the same time, the computer can display combustion test by visual frequency. At the same time, computer software can record dropping time, collapse time, temperature value and display temperature curve and other test related information.
2. One wind speed sensor, 0-10M/S, with an accuracy of 0.1M/S;
3. Two cameras, including a computer display device 2.
4. K-type thermocouple: with stainless steel sheath, the temperature range is 0-1038 degrees, the temperature accuracy is (+0.1%) and the thermocouple wire is 500 feet.
5. ADAM-4118 Module: Strong 8-way Thermocouple Input module, 8-way independently configurable differential channel; Wide temperature operation; Wider operating temperature: -40-+85 degrees C; High noise resistance: 1KV surge protection voltage input, 3KV EFT and 8KV ESD protection; Strong anti-interference: 1KV surge protection at power input, 3KV EFT, 8KV ESD protection, wide. Power input range: +10~+48 VDC; input range: +10~+48 VDC;
6. Two computers;
7. Three electronic control boxes;
8. One signal conversion box;
9. Field wiring.
 Electrical requirements: 220V, 50HZ, 5A
environmental requirements: temperature from 10°C to 35°humidity (65 ± 5) %
Application : building materials

|   | 
| BS 8414-1 Fire - Proof Test For Outer Wall External Thermal Insulation System Images | 
 SL-FL100 Building Material Flammability Test Furnace with Touch Screen Control
                                                                                    
                        
                        
                        
                                                            SL-FL100 Building Material Flammability Test Furnace with Touch Screen Control
                                                    
                        
                     Signal output 4-20mA SBI Building Products Single Burning Item Flammability
                                                                                    
                        
                        
                        
                                                            Signal output 4-20mA SBI Building Products Single Burning Item Flammability
                                                    
                        
                     Timing accuracy <1s / h Critical Radiant Flux Flammability Testing Equipment For
                                                                                    
                        
                        
                        
                                                            Timing accuracy <1s / h Critical Radiant Flux Flammability Testing Equipment For
                                                    
                        
                     DIN 4102 Building Material Flammability Testing Equipment / Smoke Density Fire
                                                                                    
                        
                        
                        
                                                            DIN 4102 Building Material Flammability Testing Equipment / Smoke Density Fire
                                                    
                        
                     Temperature accuracy ± 0.1 ℃ Building Material Flammability Testing Equipment GB
                                                                                    
                        
                        
                        
                                                            Temperature accuracy ± 0.1 ℃ Building Material Flammability Testing Equipment GB
                                                    
                        
                     SL-DBF Air Volume of Blower (1-5) m³/min Fireproof Coating Tester (Method of
                                                                                    
                        
                        
                        
                                                            SL-DBF Air Volume of Blower (1-5) m³/min Fireproof Coating Tester (Method of
                                                    
                        
                     SL-FL002 0-100 L/min Steel-Structure-Fireproof-Coating-Sample-Testing-Furnace
                                                                                    
                        
                        
                        
                                                            SL-FL002 0-100 L/min Steel-Structure-Fireproof-Coating-Sample-Testing-Furnace
                                                    
                        
                     SL-7602 Temperature of sample 23±2°C NBS Smoke Density Chamber Tester
                                                                                    
                        
                        
                        
                                                            SL-7602 Temperature of sample 23±2°C NBS Smoke Density Chamber Tester
                                                    
                        
                     Stainless Steel Flammability Testing Equipment, UL 790 Fire Test System for Roof
                                                                                    
                        
                        
                        
                                                            Stainless Steel Flammability Testing Equipment, UL 790 Fire Test System for Roof
                                                    
                        
                     Stainless Steel Building Material Flammability Testing Equipment Ignitability
                                                                                    
                        
                        
                        
                                                            Stainless Steel Building Material Flammability Testing Equipment Ignitability